Oxygen Not Included

Oxygen Not Included

117 ratings
HVAC Expansion
3
   
Award
Favorite
Favorited
Unfavorite
Compatibility: Base Game, Spaced Out!
File Size
Posted
Updated
2.185 MB
27 May, 2021 @ 5:04pm
25 May @ 10:01am
10 Change Notes ( view )

Subscribe to download
HVAC Expansion

Description
HVAC Expansion
A mod adding four new buildings for all your HVAC and HVAC-adjacent needs.

Supported Game Versions
  • Base Game
  • Spaced Out

Features
  • Thermo Aquacooler: Works like an inverse Aquatuner, cooling it's surroundings instead of heating them.
  • Thermo Conditioner: Works like an inverse Thermo Regulator, cooling it's surroundings instead of heating them.
  • Auto Evaporator: Heats and evaporates piped liquids, but dumps them if they're not hot enough.
  • Auto Condenser: Cools and condenses piped gases, but dumps them if they're not cold enough.

Note, only gases that fully evaporate and liquids that fully condense without any byproducts can be piped into the Auto Condenser and Auto Evaporator. All others will cause "Wrong Element Damage".

Q&A
Q: Why don't you add versions of the buildings that cool/heat faster for more electricity.
A: They wouldn't present any unique challenges compared to the regular versions of these buildings. More powerful buildings aren't off the table, I just don't want using them to be too easy.

Mod Compatibility
  • Customize Buildings: All buildings added respect the max pipe pressure and percent throughput options.

Credits
  • Building Art/Animations: 3GuB

Having trouble updating?
If you are unable to update HVAC Expansion, you need to install Mod Updater and force update this mod. If that still doesn't work, go into Mod Updater's settings in the Mods menu and click "Reset to Default" then "Okay". It should then prompt you to restart the game, which should fix the issue.

Issue reporting
If you find an issue with the mod, please report it on the issue tracker[github.com] as I will be more likely to see it there than in the comments.
121 Comments
RedstoneParadox  [author] 2 Jun @ 3:37pm 
Also, is it cooled enough?
RedstoneParadox  [author] 28 May @ 4:54pm 
Are you sure you have version 2.2.1?
Wolves Hero 28 May @ 1:12pm 
Bugged, steam can't turn to water, I tried reduced to 100g/s none worked still dumped steam bottles. Auto Condenser not worked. Just use water pipe cooler or solid conveyor cooler will condenser worked great.

https://steamproxy.com/sharedfiles/filedetails/?id=3489332047
RedstoneParadox  [author] 25 May @ 10:02am 
Figured out the actual issue; should be fixed now.
RedstoneParadox  [author] 25 May @ 9:43am 
So the issue is that the fields in the code that I believed to represent the transition temperatures of an element are not actually the transition temperatures of an element, so now I'm a bit stuck as I don't know where in the code the transition temperatures are actually found.
RedstoneParadox  [author] 25 May @ 8:13am 
I believe I have found a fix for the autocondenser/evaporator issue.
Shrglwyddes 3 May @ 9:15am 
Autocondensor receiving hydrogen never liquified it, even when hydrogen is nearly liquid already. dropped canisters and never outputted liquid. Gas Ethanol output had double the heat. Do you need a log?
MiserableGamer 24 Apr @ 7:49am 
Why does the auto condenser just drop steam out in canisters?
SirTubbz 13 Apr @ 10:02pm 
and it only occurs if nuclear waste is sitting inside of a location for too long. its a unique property only for nuclear waste.
SirTubbz 13 Apr @ 10:00pm 
i think they meant in the fact that if you pipe nuclear waste through an aquatuner it can cause the aqua tuner to leak the waste periodically. the aquatuner in of itself doesnt actually leak nuclear waste.